Ambient Air Samplers

High-quality sampling equipment for environmental monitoring

This line of Ambient Air Samplers is dedicated to evaluating parameters such as particulate matter, PM fractions, and inorganic or organic compounds. With this advanced sampling equipment, it’s possible to accurately measure and analyse air quality in various outdoor environments, enabling to make informed decisions about health and safety.

QB1/QB1e

Portable constant flow samplers | Ambient Air Samplers

The QB1 is a family of portable constant flow samplers, designed for use in a variety of air sampling applications requiring low to mid-flow capabilities.

Built with the everyday technician in mind, the QB1 is easy to use, rugged, and reliable. It features built-in protections for particulate matter and liquids, which are the primary causes of damage to the pump and dry gas meter.

For those needing manual isokinetic sampling, the QB1e line can be synchronised with ST2 speed and flow meter.

All versions of the QB1 are capable of automatic pressure drop compensation, ensuring high flow constance even during long-term operations.

Equipped with a dry gas meter, high precision flowmeter, and thermometer for volume normalisation, the QB1 meets industry standards. Additionally, the pneumatic circuit has been designed to eliminate flow pulsations resulting from the use of diaphragm pumps.

Choose the QB1 for reliable and precise ambients air samplers in a portable and convenient package.

Meets and exceeds the requirements of UNI EN 12919, standard for environmental samplers and for ISO EN 9096, EN 14385 and EN 13649 emission sampling methods:

    • PM10 and PM2.5 (ISO23210 VDI2066/10)
    • HCl (EN1911, EPA50, EPA51)
    • Dust (EN 13 284-1 and EPA5)
    • Heavy metals (EN14385 and EPA 60)
    • Insitu Velocity and Flow rate determination in accordance with EN 16911-1 and EN 15259

MAIN FEATURES

Constant flow rate Automatically compensates for pressure drops
Highly versatile Can be used in various applications, from emissions testing to industrial hygiene
“Leak-free” diaphragm used to pump resistant to aggressive compounds Offers the option of using rotary pumps
Compact, ergonomic design Offers exceptional strength with low weight

CF1/CF1-UR

Flow Calibrator | Ambient Air Samplers

State-of-the art flow calibrator that verifies and calibrates personal, environmental, or emissions samplers.

Flow rage available

  • from 0.45 nl/min to 45 nl/min
  • from 0.050 nl/min to 5.000 nl/min

The CF1 is a versatile device capable of calibrating no only the flow rate of the samplers but also ambient pressure, ambient temperature (UR version), relative humidity, and the volume of air passing through the cell. With the CF1, you can perform multiple calibrations using just one device.

The CF1 is also available in the CF1-UR version, which features an external sensor for measuring ambient temperature and relative humidity of the air.

Meets and exceeds the requirements of EN 12341 and EN 16450 standards:

    • PM10 and PM2.5 (ISO23210 VDI2066/10)
    • HCl (EN1911, EPA50, EPA51)
    • Dust (EN 13 284-1 and EPA5)
    • Heavy metals (EN14385 and EPA 60)
    • Insitu Velocity and Flow rate determination in accordance with EN 16911-1 and EN 15259

MAIN FEATURES

Measures the flow rate in real-time, both during suction an delivery Displays the measurement data in its screen and can acquire the data in both gas conditions (Pamb and Tgas) or normalized conditions.
The UR version of the CF1 is equipped with a combined external sensor for measuring relative humidity and ambient temperature Can provide flow rate data in both current and anhydrous conditions
Equipped with ambient temperature and pressure sensors Can be used to calibrate these parameters on samplers
CF1 features an integrated flow rate reading that measures the volume of gas sampled during a test, whether under normal or current conditions This feature also enable to utilize CF1 for verifying the reading of volumetric meters.
Supplied with CF1-Link software and USB key for wireless connection to a windows PC. Allows the visualisation of instantaneous data and downloading the acquired data.
4000 mA rechargeable lithium polymer batteries with anatomy up to 8 hours. USB Type-C power port enables to recharge directly on the field or connect to a power bank to extent the equipment autonomy.

GIANO BC1

Black Carbon Sequential PMx Sampler | Ambient Air Samplers

Giano BC1 is an innovative Sequential PMx Sampler equipped with a real-time Black Carbon analyzer directly integrated into the sampling filter. This groundbreaking system was developed through a collaboration between PM_Ten, a spin-off of the University of Genoa responsible for the design, and Dado lab, which handled the engineering and implementation within their sequential sampler.

Giano BC1 holds the distinction of being the world’s first PMx sampling system that can accurately measure Black Carbon concentration in real time, directly on the filter being sampled. This advanced technology represents a significant advancement in air quality monitoring and analysis.

Ambient Analyzer-Aquagas

The Giano BC1 black carbon Sequential PMx Sampler uses a patented, innovative approach to measuring black carbon concentration that differs from traditional analyzers. By measuring the reflectance of the laser beam instead of using transmittance, the Giano BC1 achieves a linear correlation to the absorbing coefficient (ABS), resulting in highly accurate and reliable data.

Integrating the BC sensor onto the sequential sampler has the significant benefit of providing real-time readings during sampling operations directly on the field.

To comply with the requirements of method EN12341:2014, the Giano BC1 includes a liquid cooler Peltier cell conditioning system. This system effectively maintains the temperature of exposed filters below 20°C when the ambient temperature exceeds 23°C.

MAIN FEATURES

Real-time determination of particulate matter fractions Provides instant data for analysis
Stand-alone or integrated systems Can be used as a stand-alone system or integrated with our environmental samplers for greater flexibility
Black Carbon measurement Measures directly on the sampling filter, making it the first of its kind in the world
Portable and easy to use Lightweight and easy to use, making it ideal for both indoor and outdoor environments
Customisable configurations Ensures that clients receive the best solution for their unique requirements
Accurate and reliable data Lightweight and easy to use, making it ideal for both indoor and outdoor environments

PMx | Giano & Gemini

Sequential Samplers | Ambient Air Samplers

The PMx sequential samplers Mod. Giano and Gemini enhance practicality, portability, and user-friendliness compared to other options available. Both models share a multi-purpose core unit (MPC) that enables sequential sampling on a single or double channels. The MPC concept allows for outdoor cabinet installation or 19″ rack installation in shelters or mobile labs.

The design of these samplers places significant emphasis on systems engineering, reducing the number of parts to increase reliability while also reducing the size and weight of the samplers. In fact, Giano and Gemini weigh only 35 kg (excluding the pump/s and support stand).

The MPC and outdoor cabinet are designed with forced internal air recirculation, ensuring that the ventilation tube, filter under sampling, and exposed samples are at ambient temperature. The optional air conditioning unit is necessary for applications in environments where ambient temperatures can be particularly high. It maintains filter area temperature below 25°C in case of ambient temperature exceeding 25°C. The air conditioning unit is located beneath the cabinet and provides high cooling performance. Unlike other solutions, the air conditioning system does not require special protections or insulation for the filter tanks, which can still be easily accessed and changed in the field.

Meets and exceeds the requirements of EN 12341, ISO 14644 and GMP standards:

    • PM10 and PM2.5 (ISO23210 VDI2066/10)
    • HCl (EN1911, EPA50, EPA51)
    • Dust (EN 13 284-1 and EPA5)
    • Heavy metals (EN14385 and EPA 60)
    • Insitu Velocity and Flow rate determination in accordance with EN 16911-1 and EN 15259

MAIN FEATURES

High-performance sequential sampling on single or double channels using a multi-purpose core unit (MPC) User-friendly interface with a high-resolution color LCD display
Forced internal air recirculation in the MPC and outdoor cabinet to maintain ambient temperature for sampling and exposed samples Optional air conditioning unit for use in high-temperature environments to maintain filter area temperature below 25°C
Designed for easy transportation and installation, with the option for outdoor cabinet installation or 19″ rack installation in shelters or mobile labs Data logging capabilities with internal memory storage and USB port for external storage
Weather sensors included to provide additional environmental data Ability to customize sampling schedule and parameters to fit specific needs and requirements

1PMx

Sequential Samplers | Ambient Air Samplers

The 1PMx samplers are the single-filter iteration of the latest sequential samplers, Giano and Gemini. They come equipped with a compact version of the Giano/Gemini electronic core unit that has been specially developed to be adaptable for various applications while maintaining a high level of reliability and sturdiness.

Meets and exceeds the requirements of EN 12341, ISO 14644 and GMP standards:

    • PM10 and PM2.5 (ISO23210 VDI2066/10)
    • HCl (EN1911, EPA50, EPA51)
    • Dust (EN 13 284-1 and EPA5)
    • Heavy metals (EN14385 and EPA 60)
    • Insitu Velocity and Flow rate determination in accordance with EN 16911-1 and EN 15259

MAIN FEATURES

Sequential sampling system with one or two filter channels for collecting airborne particulates Multi-purpose core unit (MPC) for managing the sequential sampling process
Equipped with a high-resolution color LCD display for easy monitoring and status reporting Forced internal air recirculation to maintain ambient temperature for sampling and exposed samples
Optional air conditioning unit for use in high-temperature environments to maintain filter area temperature below 25°C Low part count and reduced weight for increased reliability and ease of handling
Data logging capabilities Internal memory storage and USB port for external storage

1PMxHV

High Volume Samplers | Ambient Air Samplers

The 1PMx samplers are the single-filter iteration of the latest sequential samplers, Giano and Gemini. They come equipped with a compact version of the Giano/Gemini electronic core unit that has been specially developed to be adaptable for various applications while maintaining a high level of reliability and sturdiness.

These ambient samplers are high-volume instruments suitable for determining particulate matter and other substances such as IPA, PCDD/PCDF, or heavy metals. They are compliant with standards for single particulate phase and for particulate and gas phase. The flow rate of these samplers ranges from 100 to 600 l/min.

Meets and exceeds the requirements of EN 12341, ISO 14644 and GMP standards:

    • PM10 and PM2.5 (ISO23210 VDI2066/10)
    • HCl (EN1911, EPA50, EPA51)
    • Dust (EN 13 284-1 and EPA5)
    • Heavy metals (EN14385 and EPA 60)
    • Insitu Velocity and Flow rate determination in accordance with EN 16911-1 and EN 15259

MAIN FEATURES

High-volume air sampling with flow rates ranging from 400 to 1200 l/min Sequential sampling system with a single filter for collecting airborne particulates
Equipped with a compact and reliable electronic core unit developed specifically for various applications Low weight and compact design for ease of handling and transportation
High-resolution color LCD display for easy monitoring and status reporting Forced internal air recirculation to maintain ambient temperature for sampling and exposed samples
Optional air conditioning unit for use in high-temperature environments to maintain filter area temperature below 25°C Data logging capabilities with internal memory storage and USB port for external storage

TARGETED POLLUTANTS

POPs – persistent organic pollutants
POPs have been discovered to be the relevant part of emissions to the environment causing health effects, including dioxins (PCCD/F), polychlorinated biphenyls (PCBs), polyaromatic hydrocarbons (PAHs), hexachlorobenzene (HCB) and others. These compounds have a high stability, low volatility and are degraded very slowly. Due to the lipophilic character, an accumulation in the human body takes place.

Fine & Coarse dust
Fine dust is the portion of solids in gases being the focus of concern for pulmonary health effects. ParTrace® cartridges trace the fine dust fraction of general concern, PM10, PM2.5, PM1, and splits them in the respective fractions within one sampling run.

Volatile Organics Compounds

Odour indicator Components

SPECIFICATIONS

Isokinetic Sampler

Standard Probes

Gas Chiller

Heated Sampling Probe

Constant Flow Sampler

© Copyright - AquaGas Pty Ltd | ABN 46164822897. All Right Reserved