The 529® FID detector is a carbon atom counter. A sample is introduced into a micro flame lit by hydrogen and air (1:10 ratio), where the electrical charges generated by the oxidation of Cx to CO are proportional carbon content in the sample. The electrical charges are collected by two polarised electrodes and converted by an electrical circuit into an electronic signal. The PCF’s Mod. 529 NMHC (Non Methane Hydrocarbon) gas chromatographic analyser is intended for continuous monitoring of Total Hydrocarbons (THC) and the methane (CH4) fraction in ambient and indoor air.
Combination of GC and FID methods for Online monitoring of THC, CH4 and NMHC | Proprietary micro FID detector |
Keyboard / LCD display interface for configuration & calibration | Built-in automatic ignition |
Discrete gas sampling system (eductor) | Fully automatic standalone system for fast, accurate and reliable analysis of THC, CH4 and NMHC |
GAS | FULL RANGE | LoD |
---|---|---|
THC | 10 to 500 ppm | 0.02 ppm |
CH4 | 10 to 500 ppm | 0.02 ppm |
NMHC | 10 to 500 ppm | 0.02 ppm |
The separation of methane fraction is based on the chromatographic method. Once specified the CH4 is measured separately and then subtracted from Total Hydrocarbons concentrations. The measuring sequences are managed by the built-in 10 port rotation valves enabling sequential measurement of THC, CH4 and NMHC. A zero calibration cycle triggered automatically before each measuring cycle guarantees a high signal stability and efficient drift compensation.
The same technology can be adapted to specific VOCs air quality monitoring. The coupling of gas chromatography separation with state of the art FID detector allows accurate and reliable measurement of Benzene (C6H6), Ethylene (C2H4), Propylene (C3H6), Styrene (C8H8), Acetone (C3H6O), Formaldehyde (CH2O) and many others VOCs in ambient and indoor air.
GAS | FULL RANGE | LoD | ACCURACY |
---|---|---|---|
Benzene C6H6 | 0-10 / 0-20 / 0-50 / 0-100 /0-200 / 0-500 ppm | 0.05 ppm | 1% full scale |
Ethylene /Ethylene Oxide (ETO) C2H4 | 0-10 / 0-20 / 0-50 / 0-100 /0-200 / 0-500 ppm | 0.02 ppm | 1% full scale |
Propylene / Propylene Oxide C3H6 | 0-10 / 0-20 / 0-50 / 0-100 /0-200 / 0-500 ppm | 0.02 ppm | 1% full scale |
Styrene C8H8 | 0-10 / 0-20 / 0-50 / 0-100 /0-200 / 0-500 ppm | 0.5 ppm | 1% full scale |
Acetone CH36O | 0-10 / 0-20 / 0-50 / 0-100 /0-200 / 0-500 ppm | 0.5 ppm | 1% full scale |
Formaldehyde CH2O | 0-10 / 0-20 / 0-50 / 0-100 /0-200 / 0-500 ppm | 0.1 ppm | 1% full scale |
529® – THC, NMHC and CH4 Online Monitoring
Typical Applications
The THC, NMHC and CH4 online FID analyser is typically designed for integration into Air Quality Monitoring Stations intended to measure continuously the concentration of Hydrocarbons and Volatile Organic Compounds. It also offers a large range of advantages for VOCs monitoring in indoor air within the frame of Occupational Health and Safety.