SmartCEMS® GHG

GHG emissions from wastewater handling

Broadly, wastewater systems contribute to Greenhouses gases (GHG) emissions not only through their significant consumption of grid electricity in most cases, but also through direct emissions of nitrous oxide (N2O) and methane (CH4). These are often called ‘fugitive’ gases because they escape from the collection and treatment systems.

CH4 emission: Wastewater contains organics, which can be biologically converted to CH4 in the absence of oxygen (i.e., under anaerobic conditions). In some parts of wastewater collection and treatment systems, anaerobic conditions prevail, leading to the formation of CH4 and its subsequent emission into the atmosphere.

N2O emission: Wastewater contains nitrogen, which needs to be removed to avoid nutrient enrichment of receiving waters. Biological nitrogen removal has been implemented at most large wastewater treatment plants in Australia. N2O is either an intermediate reaction or a by-product of the key biological reactions involved. Therefore, N2O is formed in, and could be emitted from, wastewater treatment plants.

The indirect emissions are expected to decrease substantially in the coming decade, due to both the increased recovery of energy from wastewater (biogas from anaerobic digestion) and improved efficiency of electrical energy use for wastewater treatment.

Furthermore, the current trend is towards increasing renewable energy supply, with resultant lower emission factors. Therefore, it is foreseeable that direct emissions might in future dominate the GHG profile of many wastewater treatment plants. Indeed, for some treatment plant in Australia, this may already be true.

Actual methane and nitrous oxide emissions associated with wastewater handling vary significantly, depending on the type of system and a range of operating factors.

Emissions can make up a substantial portion of direct GHG emissions reported as part of the total for water utilities that serve urban areas. The existing GHG reporting (NGER) system in Australia does not make provision for measurements or estimates of actual direct emissions of nitrous oxide and methane emissions from wastewater handling.

Understanding of greenhouse gas emissions related to wastewater handling has improved a lot in the last ten years, thanks to the efforts of researchers and the water industry, including significant contributions from Australia.

Committed to a better environment, AquaGas Pty Ltd is proud to supply and support a broad product range featuring a line of analysers tailored to the measurement of Greenhouse Gases emissions in the environment or directly at the source. Already selected by councils and water agencies, AquaGas analysers offer exclusive features implemented to fulfil the needs of today’s urban utilities and waste recycling facilities.

AquaGas online analysers are suited to a large range of applications related to Greenhouse Gas fugitive emissions such as emissions and process monitoring at

  • WTP Ponds (with sampling hood)
  • OCS odour control systems (inlet & discharge)
  • Biogas plants (digesters, engine feed, engine emissions…)
  • And Landfills (fenceline, landfill gas…)

When used to their full extent, the expanded capabilities offered by accurate and reliable analysers can bring real benefits by providing fast access to detailed GHG emissions data and an accurate real time overview of operating conditions at urban utilities and industrial sites.

SmartCEMS® GHG

Having the N2O nitrous oxide, CH4 methane, and CO2 carbon dioxide measurements available in real time ensures greater predictivity and broader scope of fugitive emissions, allowing process problems to be resolved before they escalate.

The SmartCEMS® GHG sensor technology provides real-time continuous and simultaneous monitoring of CH4, CO2, N2O and O2 at wastewater plants, waste recycling facilities, landfill (…). With fast response times and no cross-sensitivity to any other gases in the stream, including CO and H2S, the SmartCEMS GHG does not require reference or carrier gas systems. 

The SmartCEMS® GHG combines Non-Directive Infrared, Electrochemical, Photoionization and Paramagnetic technologies in the same analyser resulting in unique measurement possibilities including complex gas sensors configurations with a large selection of dynamic measuring range (ppm to %).

The Smart CEMS® offers multiple configurationsof sensors and methods suited to the fugitive emissions at industrial sites and urban utilities. Here are the measuring parameters for the most common gases. For other gases or different measuring ranges (MR), please consult us.

GAS

ANALYSIS METHODRANGE | RESOLUTION
ACCURACYTIME (T90)
CO Carbon Monoxide
Non-Directive IR0-1% | 0.01%± 10ppm abs. 50 sec
N2O Nitrous Oxide
Non-Directive IR2 000ppm | 1ppm
± 1ppm abs.
50 sec
CH4 Methane
Non-Directive IR20, 000ppm | 1ppm± 10ppm abs.
50 sec
CO2 Carbon Dioxide
Non-Directive IR25% | 0.1%
± 0.5% abs.
50 sec
O2 Oxygen

Electrochemical, Partial Pressure20.95% | 0.01%
± 0.1% abs. or 5% rel
45 sec
O2 Oxygen
Electrochemical, Partial Pressure
100.00% | 0.01%
± 0.1% abs. or 5% rel
45 sec
O2 Oxygen
Paramagnetic
25.00% | 0.01%
± 0.1% abs. or 5% rel.
45 sec
O2 Oxygen
Paramagnetic100.00% | 0.01%
± 0.1% abs. or 5% rel.
45 sec

Available in single or multistream configuration, the SmartCEMS GHG® associated gas sampling and conditioning system features a multistage particulate filtration system, a powerful dew point stabilizer (Peltier, Nafion or dual outputs), a variable speed sampling pump and continuous removal of sample condensates.

In addition to its exclusive analytical capabilities, the SmartCEMS concept offers an ease of use for operation and maintenance tasks. All system components are field replaceable including the measuring cells delivered pre-calibrated to site. The SmartCEMS GHG® offers enhanced simplicity, making it easier for operators at any level of experience to access or relay key operational and maintenance-related data. This concept prevents unnecessary downtime and minimizing the risk of potential damage to key process plant or impaired hydrogen quality.

The inclusion of features such as remote connectivity allows the fast collection of diagnostics information, with engineers able to perform actions such as fault tracing or changes to an instrument’s configuration without having to be physically present.

IEC conformity

AquaGas analysers for the greenhouse gases monitoring complies in all aspect with the IEC60079-2 standards. AquaGas online analysers for GHG emissions monitoring are available in Purged and Pressurised (P&P) enclosure or IECEx certified version.

AquaGas is supporting the global industrial community with high performance environmental and process monitoring systems (Continuous Emissions Monitoring Systems, Air Quality Monitoring Systems, Online process analysers, Water Quality Monitoring Systems and tunnel sensors) specifically designed and built to meet your application requirements.

AquaGas SmartCEMS® solution

AquaGas is excited to increase its range of smart sensors with the release of a new branded CEMS (Continuous Emissions Monitoring System) recently acquired through an OEM with MADUR (Poland) and available across Oceania: the MAMOS.

The MAMOS SmartCEMS® is an online monitoring system designed by MADUR and integrated by AquaGas for the ANZ market which responds to industrials and environmental authorities today’s demand for a large range of industrial applications including small to large combustion plants (power station, paper mill, cement plant…), WTE (waste to Energy) installations as well as biogas, syngas and biomass generators.

Thanks to its modular and adaptive design the Mamos allows combining multiple sensors (PID, low and high range NDIR, Electrochemical, Thermal Conductivity) with applications specific sampling systems (Direct extractive heated and standard sampling train, Peltier cooler, Nafion membrane…). All system components are field replaceable and comes with a 24 months warranty.

Available as standalone unit, single analyser or redundant systems (fully backed up with manual and automatic redundancy) the Mamos SmartCEMS® is offered as a complete stationary CEMS for permanent installation or long term rental. AquaGas global service includes the various level of associated services (initial and final installation, commissioning, long term or punctual service agreement as well as the supply of consumables and critical spares for periods up to 5 years.

Moreover the MAMOS SmartCEMS® ensures minimal investment and extremely low ownership costs for trouble free environmental monitoring and process control operations while complying with Australians states regulations.

Here are some of the MAMOS SmartCEMS® main features:

  • Suited to complex gas matrix with accurate measurements of a large selection of gases: H2S, CO, CO2, HCl, SOx, NOx, H2, VOCs, CxHy, O2, NMHC and more.
  • Designed for harsh operating conditions with high dust load and elevated moisture content
  • Peltier, Nafion and standard sample conditioning sampling system
  • Builtin data logger
  • Reporting of normalised concentrations (mg/Nm3 or ppm) through analogue outputs, ModBus
  • Standalone and redundant systems with DAHS
  • Madcom acquisition and configuration software
  • In depth filtration with three stage particulates filtration (insitu with sequential backflush, heated filter, condensate trap and fine safety filter)
  • Full remote access
  • Multistream monitoring

A 550 Industrial Handheld Analyser

O2, CO, NO, NO2, NOx and SO2

Compact, robust and extremely accurate the A 550 INDUSTRIAL® Handheld Analyser is all that is required to perform a complete analysis and inspection of small, medium and large installation of combustion (kiln, burner, furnace…) and associated Gas Treatment Center. The A 550 INDUSTRIAL® is a handheld analyser designed to be used in tough industrial heat processes. With its stainless steel sintered insitu filter and built in Peltier cooler, the A550i fits the requirements of the most demanding applications especially when it comes to high moisture content and heavy dust loads.

Wohler Measuring Instruments

A 550 INDUSTRIAL® Handheld Emissions Analyser & other products

Wohler analysers and testing instruments are a byword for quality and just what you need to analyse and test heating systems, flue gas systems, ventilation systems and buildings.

MADE TO MEASURE

Environmental Monitoring and Process Control

AquaGas is supporting the global industrial community with high performance environmental and process monitoring systems (Continuous Emissions Monitoring Systems, Air Quality Monitoring Systems, Online process analysers, Water Quality Monitoring Systems) specifically designed and built to meet your application requirements.

WT1 Fence Line Monitoring Solution

Fenceline Monitoring Solution for realtime mapping of physicals, chemicals and biologicals air pollutions.

MADE TO MEASURE” for the growing demand for flexible and affordable air pollution monitoring solutions, the WT1  is a multiparameter Fence Line Monitoring System easily deployable for smart cities mapping, roadside monitoring, air pollution and odours control at industrial sites, remediation sites as well as background air studies and environmental impact assessment. The WT1 Fence Line Monitoring System is designed by Ellona Senses & Instrumentation for realtime measurement of air quality, noise, odours and vibrations in urban and rural area. 

Autonomous & Wireless, WT1® Watchtower fenceline monitoring system is designed for air pollution monitoring, environmental impact assessment and air quality control applications in urban and industrial areas. WT1® fenceline monitoring system consists in a network of field-based Gas & Odours monitoring stations with high precision sensors for low ppb gas concentrations in ambient air (H2S, RSH, NO2, NH3, SO2 …) in addition to VOC, odours, noise and particulates (from 0,3 to 17 µm). With its cutting edge cloud based data processing system (Rubix Soft SAS), the WT1® provides secured access from PC, Tablets or Phone to realtime reading, average, trends and  mapping of gas concentration with alarms and instrument status. The WT1® also offers key functions for odours surveys, plume prediction and air pollution impact assessment such as the ability to correlate high accuracy measurements in ppm, ppb or OU/M3 with sensory perception from multiple users (inspectors, surveyors or operators) and locations

WT1® fenceline monitoring system complies with

• Odour unit (EN 13725, ASTM E679)

• USEPA ( 40 CFR Part 53)

• EU ( 2008 /50/EC)

  • Scalable monitoring solution

    Modular and scalable, the WT1® fenceline monitoring system network is sized to your needs. Clear and accurate environmental data from Standalone analyser or sensors network  are available source by source, site by site or on a regional scale. Scalable instrument network for cities, large remediation sites, industrial areas, the WT1® fenceline monitoring system provides real-time air pollution data for efficient management of chemicals and olfactory pollution.

  • Realtime impact assessment

    Real Time alarm, customised mapping with online air pollution and nuisances data available from the Ellona Software Platform secured website, using any web browser to access safely your data, 24/7, anywhere in the world, the WT1 is a versatile tool for impact assessment and air pollution control in and around construction sites, industrial facilities.

  • Increased air pollution control capabilities

    Correlation with reference instruments can be provided via automatic on line sampling and dynamic olfactometry or field olfactometry and a simple correlation model building.

    Ideally suited to control biofilters, scrubbers and other odour control systems, WT1® fenceline monitoring system is typically designed to measure continuously the concentration of  a wide range of air pollutants and odour precursors including but not limited to  H2S, Mercaptans, Amines, NH2, SO2, CO2, CO, CL, C2HO4, H, HCl, HCN, NH3, O3, NO2, PH3, H2S, O2, SO2, CH4, NO, VOC, PM particles from 0,3 to 17 um.

  • Source identification

    Weather correlated AQM data with Temperature, Relative Humidity, wind speed and direction for Dynamic 3D mapping of dispersion plumes and automatic air pollution report with source identification in rural, industrial and urban areas.

AquaGas Pty Ltd

Integrated systems and Customised Services

aquagas_logo_500px

AquaGas Pty Ltd is committed to deliver turnkey monitoring solutions customised to today’s industrials needs


  • ONLINE WATER ANALYSERS

    Ammonium, Free or Total Chlorine, Hydrazine, Morphine, Phenol, Sulfates, Colour, Silica, Phosphates (Orthophosphates), Hardness, Aluminium, Chromium VI, Iron, Nickel, Lead, Zinc, TH, Alkalinity, Chlorides, Cyanides, Fluorides, Peracetic acid VFA, CaM…

    SERES® online water quality analyser offers multiple sensor and method configurations. Here are the typical  measuring parameter calibrated on the TOPAZ unit. For other parameters or different measuring ranges (MR), please consult us.

  • EMISSIONS AND PROCESS GAS ANALYSERS

    NO, NO2, NOx, SO2, CO, HCl, CO2, H2O, H2S, NH3, N2O, COS, SO3, CH4, HF, HCN, H2…
    Our strong partnerships implemented with world leading CEMS and Process gas analyser manufacturers as well as local distributors,  provide AquaGas with an extensive range of technologies, diverse measuring principle and sampling methods to design and build cost effective, versatile and high performance systems composed of instruments specifically selected  in consideration of the applications.

  • DATA ACQUISITION AND REPORTING SOFTWARE

    Data Aquisition Software (CDAS) is a fully MCERTS accredited (parts A, B, C1 & C2) real time data acquisition software – now available for touch screens and windows 10. CDAS is customisable and flexible, allowing it to collect raw data from a range of instruments for CEMS

  • ISOKINETIC SAMPLING CONSOLE

    Isokinetic sampler developed for short to medium term emissions monitoring, fulfilling all the requirements of the dioxins and persistent organic compounds (POPs), PCBs, metals, HCB and fine dust measurement standard within the same sampling train

  • HANDHELD and PORTABLE GAS ANALYSERS

    O2, CO, CO2, NO, NO2, SO2, H2S, H2, CL2, N2O and VOCs

    Professional flue gas analyser combining high quality of sample conditioning with great measurement accuracy for continuous emissions monitoring or online process measurement of up to 9 gases simultaneously.