AquaGas is excited to increase its range of smart sensors with the release of a new branded CEMS (Continuous Emissions Monitoring System) recently acquired through an OEM with MADUR (Poland) and available across Oceania: the MAMOS.

The MAMOS SmartCEMS® is an online monitoring system designed by MADUR and integrated by AquaGas for the ANZ market which responds to industrials and environmental authorities today’s demand for a large range of industrial applications including small to large combustion plants (power station, paper mill, cement plant…), WTE (waste to Energy) installations as well as biogas, syngas and biomass generators.

Thanks to its modular and adaptive design the Mamos allows combining multiple sensors (PID, low and high range NDIR, Electrochemical, Thermal Conductivity) with applications specific sampling systems (Direct extractive heated and standard sampling train, Peltier cooler, Nafion membrane…). All system components are field replaceable and comes with a 24 months warranty.

Available as standalone unit, single analyser or redundant systems (fully backed up with manual and automatic redundancy) the Mamos SmartCEMS® is offered as a complete stationary CEMS for permanent installation or long term rental. AquaGas global service includes the various level of associated services (initial and final installation, commissioning, long term or punctual service agreement as well as the supply of consumables and critical spares for periods up to 5 years.

Moreover the MAMOS SmartCEMS® ensures minimal investment and extremely low ownership costs for trouble free environmental monitoring and process control operations while complying with Australians states regulations.

Here are some of the MAMOS SmartCEMS® main features:

  • Suited to complex gas matrix with accurate measurements of a large selection of gases: H2S, CO, CO2, HCl, SOx, NOx, H2, VOCs, CxHy, O2, NMHC and more.
  • Designed for harsh operating conditions with high dust load and elevated moisture content
  • Peltier, Nafion and standard sample conditioning sampling system
  • Builtin data logger
  • Reporting of normalised concentrations (mg/Nm3 or ppm) through analogue outputs, ModBus
  • Standalone and redundant systems with DAHS
  • Madcom acquisition and configuration software
  • In depth filtration with three stage particulates filtration (insitu with sequential backflush, heated filter, condensate trap and fine safety filter)
  • Full remote access
  • Multistream monitoring

City Of Gold Coast

Committed to a better environment and sustainable future, AquaGas Pty Ltd is proud to assist the City of Gold Coast with the installation of a new gas monitoring system used to optimize the production of biogas as part of the government’s renewable energy target. Unlike natural gas derived from fossil fuels, Biogas is a mixture of gases produced by the fermentation process of fresh waste material in anaerobic (without air) conditions making biogas a renewable “natural gas” resource. With a complete monitoring system currently online, this new installation expands AquaGas references in the field of process control and environmental compliance at Biogas plant.

Biogas Monitoring Systems

for the City of Gold Coast

Biogas plants help to significantly reduce fugitive emissions of greenhouse gases and odour precursors while recovering energy for better process efficiency. There are multiple advantages in measuring biogas composition along the fermentation process and accurate online reading of CH4, H2S, CO2 and O2 have become our clients key factors in terms of plant operations and environmental compliance.

City of Gold Coast entrusted AquaGas Monitoring Systems for the supply, installation and commissioning of a biogas monitoring system ABYSS ABG as required to operate their three digesters each holding 27 ML, 15 ML and 15 ML each respectively. The turnkey and customised system delivered and commissioned by AquaGas enables safe plant operations, combustion efficiency and high reliability thanks to is a process sampling system with continuous liquid drain, dual stage pressure rated up to 10 bars, particulate filter, condensate trap and moisture alarm. At the heart of the system, the ABYSS ABG analyser from Ankersmid Sampling BVBA is fitted with high precision gas proprietary cells for simultaneous online measurements of CH4 content in % by NDIR (Non Dispersive Infra Red) and H2S traces down to 1 ppm (Electrochemical cell).

The ABYSS BIOGAS ABG and SYNGAS ASG Series are manufactured by Ankersmid Sampling BVBAANKERSMID® is well-known in the industry for more than 30 years now with subsidiaries in several countries (Netherlands, France, China, Romania, Germany, Korea etc.) and more than 100 employees world-wide assures ANKERSMID® in a leading position in the field of gas sampling and laboratory equipment. All products are designed and manufactured by ANKERSMID® Sampling Belgium including but not limited to gas sample probes, gas coolers, compact conditioning systems, NOx-converters as well as a complete range of universal gas sampling components. ANKERSMID® offering includes the most complete range of CEMS sampling system components and accessories completed with the versatile ABYSS series gas analysers. The modular and universal design of the CEMS components and accessories empowers cost effective, reliable and innovative system integration.

MADE TO MEASURE

Environmental Monitoring and Process Control

AquaGas is supporting the global industrial community with high performance environmental and process monitoring systems (Continuous Emissions Monitoring Systems, Air Quality Monitoring Systems, Online process analysers, Water Quality Monitoring Systems) specifically designed and built to meet your application requirements.

AquaGas Pty Ltd – Enews – Projects

AquaGas Pty Ltd is proud to advertise the acquisition of several projects within the field of Emissions Monitoring (CEMS) and Water Quality (WQMS)

These new projects provide AquaGas with solid references for applications where accurate and reliable online analysis are fundamental in terms of environmental compliance and process automation.

Here is our pick

Three Water Quality Monitoring Stations

For Sydney’s greater remediation project

After having successfully completed the commissioning of the first set of systems supplied (Four CEMS NMHC), our client, South Pacific market leader for the containment and filtration of hydrocarbons (sheen, gasoline, diesel and oils), entrusted AquaGas Pty Ltd with the supply, installation and commissioning of three water quality monitoring stations for their Wastewater Treatment Plant.

Tank Headspace Monitoring Systems

for the Oil and Gas industry

A complete tank headspace gas monitoring system supplied to the Australian leading company in wastewater treatment. The AquaGas THMS is designed to be  integrated to the mainstream of the existing installation in order to enhance the management of wastewater. The THMS is used to alternatively measure the gas composition of two wastewater storage tank headspaces from our client main plant in Sydney.

CEM and Process Analysers

in Biogas Plant

Two Biogas Monitoring Systems for H2S, O2 and CH4 online analysis at a biogas plant in Victoria. Our client, operator of 14 wastewater treatment plants and two ocean outfalls across Victoria, has selected the Mamos Biogas Analyser for its performances and reliability. The Mamos is specifically designed for online analysis of biogas primary constituents into process gas and emissions.

Sterilant Gas

in manufacturing industry

The Australia’s leading manufacturers of disinfectants for healthcare, floor maintenance and industrial cleaning products has chosen the SafeCide™ for real-time measurement of Peracetic Acid PAA concentrations in parts per million (PPM) at their main production facilities in in the Hunter Region of New South Wales. The SafeCide™ gives employees peace of mind they are safe while minimizing disruptions to production related operations. SafeCide provides fast, accurate, real-time measurements of chemical vapor – giving you the ability to prevent or address concerns in real-time.

Complete Gas Detection and Monitoring Solutions

For Worker Safety, Quality, and Productivity

 

AquaGas is supporting the global industrial community with high performance environmental and process monitoring systems (Continuous Emissions Monitoring Systems, Air Quality Monitoring Systems, Online process analysers, Water Quality Monitoring Systems) specifically designed and built to meet your application requirements.

  • ENVIRONMENTAL MONITORING
  • ENVIRONMENTAL MONITORING
  • ENVIRONMENTAL MONITORING
  • ENVIRONMENTAL MONITORING

Tank Headspace Monitoring Systems – THMS

Applications

in the Oil and Gas industry.

Water treatment plant in refineries and other oil and gas processes requires the use of tank for storage purposes and as part of the wastewater management plan. The composition of the air confined in the tank headspace provides a good indication of the level of contamination in the wastewater influents. Monitoring gas in tank headspaces also becomes mandatory when it comes to managing oils contaminated water. Explosion risks but also the corrosion and degradation factor are controlled with the blanketing whose automation can largely be optimised by the online measurement of gas concentrations in the headspace. Moreover there is a large number of compounds that will  adduce plant operators detailed information with regards to filtration and decantation processes.

Tank Blanketing Automation

Tank blanketing is the process of filling the headspace in storage vessels and reactors with an inert gas, usually to protect its contents from exploding, degrade but also to protect equipment from corrosion. As oxygen and moisture in the air can be undesired in numerous processes and applications, blanketing is done in a wide range of industries, varying from petrochemicals to food and beverage, pharmaceutical to pure water. Inerting is done for similar reasons but is not limited to storage tanks and reactors only. Any confined space can be sparged with an inert gas to create the desired atmosphere. This ranges from packing food under protective atmosphere to increase shelf life to lowering the oxygen concentration in rooms where welding takes place to reduce risk of fire.

Risks Management

Wrongly engineered or poorly maintained blanketing systems may lead to serious incidents, degraded plant operations and pollution events. A malfunctioning may cause the tank to implode or causes the leaking of air into the tank, which, as mentioned, can have consequences with regard to product quality and, depending on the stored product, can seriously increase risk of explosion.

One way to increase safety and reduce the use of blanketing gas (nitrogen, air…) simultaneously is to control inertisation as a function of gas concentration in the headspace. Depending on the product and the reason for blanketing and inerting, there are tolerances when it comes down to the maximum allowable oxygen, VOCs or other combustibles concentration. Certain monomers require zero percent oxygen to prevent polymerization. Others require a small amount of oxygen for the same reason. In the case of explosion protection, the oxygen concentration does not necessarily need to be zero. In fact for all solvents a so called limiting oxygen concentration exists. Below this concentration there is no risk of explosion. It is obvious that controlling the tank headspace purge based on the concentration will seriously cut nitrogen or other blanketing gas costs. Furthermore the measurement of gas concentrations in the tank headspace provides an important safety parameter.   Thresholds such as Limiting Oxygen Concentration (LOC), Maximum Oxygen Concentration (MOC), Lower Explosive Limit (LEL) indicate application and gas specific limits in terms of concentration.

For example, two threshold values are established for the oxygen concentration in the tank headspace, well below the Limiting Oxygen Concentration; the Lower Intervention Level and the Upper Intervention Level. These two threshold values are the set-points that control the purging sequences. The moment the oxygen concentration reaches the Lower Intervention Limit, the nitrogen flow is intermittent. Purging of the vessel is resumed when the upper intervention limit is exceeded. This means that the inerting system keeps the consumption of nitrogen minimal while safe operation is ensured.

Analyser solutions

Depending on individual process conditions and solvent; O2, H2O and LEL are usually the main parameters of interest. However when odour control is implemented NH3, H2S and VOCs can be added to the monitored parameters.

To meet the needs of the waste recycling facilities, AquaGas offers a unique fully automatic solution for realtime measurement of gas concentrations in Tank Headspaces. AquaGas THMS features the association of a MAMOS multigas analyser fitted with a combination of 9 gas proprietary measuring cells with a field proven, robust and dedicated Exproof sampling train. The system can be multiplexed for controlling up to 4 tank headspaces. Both the gas sampling probe located at the top of the tank and the sample line are temperature controlled above the gas dew point. Depending on the application, the gas can also be fitted with the optional backflush, temperature sensor, insitu filter… The onboard PLC offers a large panel of IOs as required to handle blanketing regulator, breathing valve, safety relief valve…

The THMS is integrated in Australia by AquaGas for continuous and simultaneous measurement of VOC, NH3, CO, CO2, LEL, CxHy, H2S and O2 inside tank headspaces.

Advantages of AquaGas THMS

The AquaGas THMS is a cost efficient and safe solution available in a compact wall mount IP56 enclosure that totally eliminates the need for multiple sensors and probes. The sampling probe can be mounted directly into the vessel or blanketing gas discharge piping and is rated for high dust, moisture or solvents loads. A retractable filter assembly allows cleaning of the sampling probe without the need for dismounting the probe from its matching flange. Zero calibration is performed automatically on a daily basis while span gas calibration is only required quarterly. In very critical applications, the system can be equipped with redundant probes and or sensors for additional safety and self check purposes. Compared to traditional analyser technology, the AquaGas THMS is available at only a fraction of the costs. The most valued perceived benefit however is the significant increase of safety, enormous savings on tank maintenance as well as the optimised process operations.

aquagas_logo_500px

Integrated Systems and Customised Services

For better environmental performances.

  • ONLINE WATER ANALYSERS

    Ammonium, Free or Total Chlorine, Hydrazine, Morphine, Phenol, Sulfates, Colour, Silica, Phosphates (Orthophosphates), Hardness, Aluminium, Chromium VI, Iron, Nickel, Lead, Zinc, TH, Alkalinity, Chlorides, Cyanides, Fluorides, Peracetic acid VFA, CaM…

    SERES® online water quality analyser offers multiple sensor and method configurations. Here are the typical  measuring parameter calibrated on the TOPAZ unit. For other parameters or different measuring ranges (MR), please consult us.

  • EMISSIONS AND PROCESS GAS ANALYSERS

    NO, NO2, NOx, SO2, CO, HCl, CO2, H2O, H2S, NH3, N2O, COS, SO3, CH4, HF, HCN, H2…
    Our strong partnerships implemented with world leading CEMS and Process gas analyser manufacturers as well as local distributors,  provide AquaGas with an extensive range of technologies, diverse measuring principle and sampling methods to design and build cost effective, versatile and high performance systems composed of instruments specifically selected  in consideration of the applications.

  • DATA ACQUISITION AND REPORTING SOFTWARE

    Data Aquisition Software (CDAS) is a fully MCERTS accredited (parts A, B, C1 & C2) real time data acquisition software – now available for touch screens and windows 10. CDAS is customisable and flexible, allowing it to collect raw data from a range of instruments for CEMS

  • ISOKINETIC SAMPLING CONSOLE

    Isokinetic sampler developed for short to medium term emissions monitoring, fulfilling all the requirements of the dioxins and persistent organic compounds (POPs), PCBs, metals, HCB and fine dust measurement standard within the same sampling train

  • PORTABLE GAS ANALYSERS

    O2, CO, CO2, NO, NO2, SO2, H2S, H2, CL2, N2O and VOCs

    Professional flue gas analyser combining high quality of sample conditioning with great measurement accuracy for continuous emissions monitoring or online process measurement of up to 9 gases simultaneously.

ENVIRONMENTAL MONITORING

Stack Testing

Ankersmid Sampling

APS Portable Gas Sampling System

The emission of pollutants resulting from a multitude of activities (industry, transport, …) alters the atmospheric composition and degrade air quality. Control of gaseous pollutant emissions in the atmosphere has become a major challenge for the protection of human health and the environment. To avoid these risks, the regulation has established discharge limits thresholds for certain pollutants and requires periodic inspections whose frequency depends on the type of activity (from 3 months to 3 years). Accredited stack testing companies are responsible for conducting short to medium term environmental compliance monitoring tasks in a wide range of industries and processes such as power plants and large manufacturing facilities including paper mill, foundry, waste recycling facilities,  refineries…

Prior to be analysed, the gas extracted from the discharge stack or process duct requires delicate conditioning which mainly consist of particulate filtration and moisture removal. Failure to achieve an efficient sample preparation can results in inaccurate measurements, loss of data or damaged equipment.

While stack testers and local authorities are continuously devoting time and knowledge to optimise the methods and protocols related to short to medium terms mandatory analysis campaign, ANKERSMID® has invested its long time expertise in developing the APS Portable Gas Conditioning Systems in direct collaboration with  leading stack testing companies.

As a result, ANKERSMID® Portable Sampling System APS provides stack testers with  features tailored to short term source testing in a robust and light weight design. The complete systems responds to today’s demand in terms of operation and compliance.

ANKERSMID®

Portable Sampling System APS

ANKERSMID® Portable Sampling System APS is a complete gas sampling train composed of:

  • APP Heated Gas Sampling probe

    High temperature filtration

  • AHL Heated Gas Sample line

    Fast and reliable sample gas transfer

  • APS Gas Sampling System

    Accurate and performant gas conditioning

APP Portable Heated Gas Sampling Probe

The APP Heated Gas Sampling Probe is a light weight sampling gun enabling high temperature filtration directly at the sampling point.

Portable probe APP trans 2

The probe is heated up to 180°C in order to maintain the sample temperature above acid gases dew point. A filter element of 150 mm is integrated, suitable for most applications up to 1g of dust per cubic meter of emissions. Thanks to its design, the filter can be replaced or checked without the need of dismounting the probe. For applications where the dust load reaches 10 g/m³, a blow-back option can be fitted. Calibration gas can be injected directly into the probe through the calibration gas port according to emission monitoring standards enforcing test gas feeding via the probe’s filter element.

MAIN FEATURES

180°C operating temperature

Integrated over temperature safety switch

Low temperature alarm contact

Test gas port according to EN14181 available as standard

Light weight

Ready to operate in 15 minutes

Low and Easy maintenance

Universal mounting clamp for heated line

Compact design and universal applicability, easy handling with mounting eye on housing (2m chain incl.)

APP150 Portable heavy duty ABS case for safe transport

AHL Heated Sample Line

AHL Heatedline-v2

The AHL Heated sample line is perfectly suited to mobile applications. It features a highly flexible smooth silicon outer jacket and can be fitted with options enabling efficient installation and operation:

  • Quick connect fittings at both ends: stainless steel pressure release connector directly inserted into the heated lines hard cap terminations (no cold spot)
  • Built-in cable with plugs to feed the APP sampling probe with power – No additional cable or power source required at the sampling location.
  • Additional inner tubes for test gas (calibration via probe filter) or compressed air (back-flush)

APS Portable Gas Conditioning System

 

portable conditioning 3xx 2

The APS portable sampling system is designed so that detailed gas analysis can be carried out at any time in any place. The entire sampling system is housed in a compact and robust carrying case which ensures safe transport and easy set-up. All the components can be easily accessed for inspection or routine maintenance. The APS concept allows you to perform gas analysis in an efficient manner, safely and with a minimum of maintenance. This system ensures reliable sample preparation without loss and prevents damage on the downstream analysis system. It is suitable for a large range of applications and has already been adopted by many stack testers around the world.

MAIN FEATURES

Fully automated

Moisture alarm (detection of sample condensates)

Extremely stable dew point +/-1 degree C

Optimal reliability

Compact and robust design

Light weight

Ready to operate in 15 minutes

Low and Easy maintenance

PFA coated heat exchanger

PTFE coated sampling pump

Preliminary sample filter

Built-in temperature controller for the heated line

AquaGas Pty Ltd

Integrated high performance monitoring solutions

aquagas_logo_500px

AquaGas Pty Ltd has the tools and technologies needed to accurately measure atmospheric emissions of gaseous pollutants helping you in improving air quality and environmental performances.

  • Portable Gas Analysers

    Multigas analysers fitted with a combination of proprietary gas cells for short term monitoring of biogas, syngas and combustion processes.

  • Isokinetic Sampling Console

    Isokinetic sampler developed for short to medium term emissions monitoring, fulfilling all the requirements of the dioxins and persistent organic compounds (POPs), PCBs, metals, HCB and fine dust measurement standard within the same sampling train

  • Data Acquisition and reporting Software

    Data Aquisition Software (CDAS) is a fully MCERTS accredited (parts A, B, C1 & C2) real time data acquisition software – now available for touch screens and windows 10. CDAS is customisable and flexible, allowing it to collect raw data from a range of instruments for CEMS

 

Ankersmid Sampling

ANKERSMID® , well-known in the monitoring industry as Ankersmid M&C, has the benefits of 30 years of experience in developing state of the art gas sampling and gas conditioning equipment tailored to CEMS (Continuous Emissions Monitoring Systems) and stack testing (short to medium term measurements). Subsidiaries in several countries (Netherlands, France, China, Roumania, Germany, Korea…) and more than 100 employees world-wide place ANKERSMID® in a leading position within the field of environmental monitoring and process control instrumentation.

CEMS and process gas analyser

A new approach to continuous gas monitoring

The Mamos is a high quality stationary monitoring system for the measurement of up to 6 gases as well as gas temperature, ambiant and differential pressures (Gas Flow) in a large field of applications.

Designed to optimise performance/price ratio, small in size and yet very skilful analyser, the Mamos is the field proven alternative for large, intricate Continuous Emissions Monitoring Systems, as it does not fall behind them concerning functionality, abilities, reliability and is far ahead in terms of expenses.

AquaGas Multigas CEMS

Online monitoring made easy

Fully automated and packed with exclusive features, the Mamos concept enlarges monitoring possibilities and respond to the today’s demands in terms of accuracy, reliability and flexibility. Each analyser is supplied with its own sampling system. The entire system is mounted on a wall mount plate and designed for installation in industrial settings and rough environment. It has a modular construction, and offer a large panel of add-ons to match site specific application requirements. The Mamos minimises the installation and ongoing operation cost until now required to fulfil your monitoring needs.

MAMOS-Multigas-analyser-CEMS-features

Multigas

Depending of the gas matrix and components to be analysed, the Mamos can be fitted with up to 6 different sensors. The combination of technologies (NDIR, TCD, PID, Electrochemical) and the addition of separate gas channels into the same instrument empower flexibility in multigas applications. A unique feature is to allocate a gas channel to sensible sensors. Its design ensures the cells have a limited exposure to gases and therefore extends considerably their respective life-time.

Process gas and emissions monitoring in combustion plants, boilers, syngas, biogas, waste recycling facilities and associated filtration systems are typical applications for multiple gas channels configuration.

In Biogas, the primary gas channel holds the CO2, CH4, Osensors while an additional separate gas channel is allocated to sensible Electrochemical sensors, H2S for example. The two NDIR gas channels can then be used for CO and VOCs.

MAMOS-CEMS-Flow diagram-2

The Mamos offers multiple sensor and method configurations. Here are the measuring parameter for the most common gases. For other gases or different measuring ranges (MR), please consult us.

Gas Analysis Method Range   I   Resolution Accuracy Time (T90) Conformity
O2

 

Oxygen

Electrochemical, Partial Pressure 20.95% |

 

0.01%

± 0.1% abs. or 5% rel. 45 sec ISO 12039,
CTM-030
O2

 

Oxygen

Electrochemical, Partial Pressure 25.00% |

 

0.01%

± 0.1% abs. or 5% rel. 45 sec ISO 12039,
CTM-030
O2

 

Oxygen

Electrochemical, Partial Pressure 100.00% |

 

0.01%

± 0.1% abs. or 5% rel. 45 sec ISO 12039,
CTM-030
CO

 

Carbon Monoxide

Electrochemical Sensor 4 000ppm |

 

1ppm

± 5ppm abs. or 5% rel. 45 sec ISO 12039,
CTM-030
CO

 

Carbon Monoxide

Electrochemical, with H2 compensation 4 000ppm |

 

1ppm

± 5ppm abs. or 5% rel. 45 sec ISO 12039,
CTM-030
CO

 

Carbon Monoxide

Electrochemical Sensor 20 000ppm |

 

1ppm

± 5ppm abs. or 5% rel. 45 sec ISO 12039,
CTM-030
CO

 

Carbon Monoxide

Electrochemical, with H2 compensation 20 000ppm |

 

1ppm

± 5ppm abs. or 5% rel. 45 sec ISO 12039,
CTM-030
CO

 

Carbon Monoxide

Electrochemical Sensor 10% |

 

0.001%

± 0.005% abs. or 5% rel. 45 sec ISO 12039,
CTM-030
CO

 

Carbon Monoxide

NDIR

 

Non Dispersive Infra Red

10% |

 

0.01%

± 0.05% abs. or 5% rel. 45 sec EN 15058 and

 

Method 10

CO

 

Carbon Monoxide

NDIR

 

Non Dispersive Infra Red

25% |

 

0.01%

± 0.05% abs. or 5% rel. 45 sec EN 15058 and

 

Method 10

CO

 

Carbon Monoxide

NDIR

 

Non Dispersive Infra Red

50% |

 

0.01%

± 0.05% abs. or 5% rel. 45 sec EN 15058 and

 

Method 10

CO

 

Carbon Monoxide

NDIR

 

Non Dispersive Infra Red

100% |

 

0.1%

± 0.5% abs. or 5% rel. 45 sec EN 15058 and

 

Method 10

CO2

 

Carbon Dioxide

NDIR

 

Non Dispersive Infra Red

5% |

 

0.01%

± 0.05% abs. or 5% rel. 45 sec ISO 12039,

 

OTM-13

CO2

 

Carbon Dioxide

NDIR

 

Non Dispersive Infra Red

10% |

 

0.01%

± 0.05% abs. or 5% rel. 45 sec ISO 12039,

 

OTM-13

CO2

 

Carbon Dioxide

NDIR

 

Non Dispersive Infra Red

25% |

 

0.01%

± 0.05% abs. or 5% rel. 45 sec ISO 12039,

 

OTM-13

CO2

 

Carbon Dioxide

NDIR

 

Non Dispersive Infra Red

50% |

 

0.01%

± 0.05% abs. or 5% rel. 45 sec ISO 12039,

 

OTM-13

CO2

 

Carbon Dioxide

NDIR

 

Non Dispersive Infra Red

100% |

 

0.1%

± 0.5% abs. or 5% rel. 45 sec ISO 12039,

 

OTM-13

CxHy

 

Total Hydrocarbons

NDIR

 

Non Dispersive Infra Red

1% |

 

0.01%

± 0.05% abs. or 5% rel. 45 sec  
CxHy

 

Total Hydrocarbons

NDIR

 

Non Dispersive Infra Red

5% |

 

0.01%

± 0.05% abs. or 5% rel. 45 sec  
CxHy

 

Total Hydrocarbons

NDIR

 

Non Dispersive Infra Red

10% |

 

0.01%

± 0.05% abs. or 5% rel. 45 sec  
CxHy

 

Total Hydrocarbons

NDIR

 

Non Dispersive Infra Red

25% |

 

0.01%

± 0.05% abs. or 5% rel. 45 sec  
CxHy

 

Total Hydrocarbons

NDIR

 

Non Dispersive Infra Red

50% |

 

0.01%

± 0.05% abs. or 5% rel. 45 sec  
CxHy

 

Total Hydrocarbons

NDIR

 

Non Dispersive Infra Red

100% |

 

0.1%

± 0.5% abs. or 5% rel. 45 sec  
NO

 

Nitric Oxide

Electrochemical Sensor 1 000ppm |

 

1ppm

± 5ppm abs. or 5% rel. 45 sec CTM-022
NO

 

Nitric Oxide

Electrochemical Sensor 5 000ppm |

 

1ppm

± 5ppm abs. or 5% rel. 45 sec CTM-022
NO2

 

Nitrogen Dioxide

Electrochemical Sensor 1 000ppm |

 

1ppm

± 5ppm abs. or 5% rel. 60 sec CTM-022
NO2

 

Nitrogen Dioxide

Electrochemical Sensor 4 000ppm |

 

1ppm

± 5ppm abs. or 5% rel. 60 sec CTM-022
SO2

 

Sulphur Dioxide

Electrochemical Sensor 2 000ppm |

 

1ppm

± 5ppm abs. or 5% rel. 45 sec  
SO2

 

Sulphur Dioxide

Electrochemical Sensor 5 000ppm |

 

1ppm

± 5ppm abs. or 5% rel. 45 sec  
H2S

 

Hydrogen sulfide

Electrochemical Sensor 1 000ppm |

 

1ppm

± 5ppm abs. or 5% rel. 70 sec  
H2S

 

Hydrogen sulfide

Electrochemical Sensor 10 000ppm |

 

1ppm

± 5ppm abs. or 5% rel. 45 sec  
H2

 

Hydrogen

Electrochemical Sensor 2 000ppm |

 

1ppm

± 10ppm abs. or 5% rel. 50 sec  
H2

 

Hydrogen

Electrochemical Sensor 20 000ppm |

 

1ppm

± 10ppm abs. or 5% rel. 70 sec  
H2

 

Hydrogen

TCD

 

Thermal Conductivity Detector

10% |

 

0.1%

± 0.5% abs. or 5% rel 45 sec  
H2

 

Hydrogen

TCD

 

Thermal Conductivity Detector

25% |

 

0.1%

± 0.5% abs. or 5% rel 45 sec  
H2

 

Hydrogen

TCD

 

Thermal Conductivity Detector

50% |

 

0.1%

± 0.5% abs. or 5% rel 45 sec  
H2

 

Hydrogen

TCD

 

Thermal Conductivity Detector

100% |

 

0.1%

± 0.5% abs. or 5% rel 45 sec  
N2O

 

Nitrous Oxide

NDIR

 

Non Dispersive Infra Red

2 000ppm |

 

1ppm

± 10ppm abs. or 5% rel 45 sec ISO 21258
N2O

 

Nitrous Oxide

NDIR

 

Non Dispersive Infra Red

5 000ppm |

 

1ppm

± 10ppm abs. or 5% rel 45 sec ISO 21258
CHF3

 

Fluoroform (Refrigerant R23)

NDIR

 

Non Dispersive Infra Red

2.5% |

 

0.01%

± 0.05 abs. or 5% rel. 45 sec  
CL2

 

Chlorine

Electrochemical Sensor 250ppm |

 

1ppm

± 5ppm abs. or 5% rel. 60 sec  
VOC

 

Volatile Organic Compounds

PID

 

Photo Ionization Detector

100ppm |

 

1ppm

± 5ppm abs. or 5% rel. 120 sec Method 21
VOC

 

Volatile Organic Compounds

PID

 

Photo Ionization Detector

1000ppm |

 

1ppm

± 5ppm abs. or 5% rel. 120 sec Method 21

Pleasant interface

Its powerful and pleasant PC interface provides operators and system integrators with a broad range of settings to adjust many aspects of the measurement tasks such as automated sampling, calibration, purge sequences, analogue outputs behaviour, data presentations…

For large sites with complex monitoring requirements, the LAN and ModBus interfaces allow implementing in an efficient way large instruments networks with master/slave configurations and user settable monitoring functions.

MAMOS-CEMS-interface

Optimised integration

This compact system is delivered ready for installation. Thanks to its small size, the system is easy to locate,  install and set-up. The routing of the cables and tubes to the instrument is simplified with all gas and electrical connections grouped onto a single plate.

MAMOS-CEMS-Connector panel MAMOS-CEMS-Connector panel-2

Advanced Features

  • Miniature and field replaceable technology
  • Standard configuration includes 6 sensors (NDIR, TCD, PID or Electrochemical)
  • Measured gases: O2, CO, CO2, CxHy, NO, NO2, SO2, H2S, H2, N2O, Cl2, VOC
  • Built-in real-time calculations for the following process parameters:

Variable Method Range   I   Resolution Accuracy Response Time (T90)
Tgas

 

Gas temperature

K-type thermocouple -50 ÷ 1000°C |

 

0.1°C

± 2°C 10 sec
Tgas

 

Gas temperature

S-type thermocouple -50 ÷ 1000°C |

 

0.1°C

± 2°C 10 sec
Tamb

 

Boiler intake air temperature

PT500 resistive sensor -50 ÷ 1000°C |

 

0.1°C

± 2°C 10 sec
DP

 

Differential Pressure

Silicon piezo-resistive pressure sensor 25hPa ÷ +25hPa |

 

1Pa (0.01hPa)

± 2Pa abs. or 5% rel. 10 sec
V

 

Gas velocity

With sampling probe equipped Pitot tube & pressure sensor 1 ÷ 50m/s |

 

0.1m/s

0.3m/s abs. or 5% rel. 10 sec
Lambda λ

 

Excess air number

Calculated 1 ÷ 10 |

 

0.01

± 5% rel. 10 sec
qA

 

Stack loss

Calculated 0 ÷ 100% |

 

0.1%

± 5% rel 10 sec
Eta η

 

Combustion Efficiency

Calculated 0 ÷ 120% |

 

0.1%

± 5% rel 10 sec
  • Large display / User friendly menu
  • Built-in gas chiller with continuous condensate removal
  • Data-logger with SD card for results collection.
  • Analogue outputs (both current and voltage) to control external devices
  • User configurable functions controlled via digital and analogue inputs
  • USB, LAN, RS485 and MODBUS

Versatile in use

The sampling system configuration can be adapted to specific monitoring needs such as multipoint monitoring, redundancy, continuous or time set measuring cycles… When sampling from wet and hot gas, moisture content, condensates and salts are continuously removed by the use of one or several gas dryer(s) (Peltier or Nafion) equipped with built-in safety filter, condensate trap and safety inline particulate filters.

Wether it uses the built-in sampling pump or the pressure from the source, the analyser is designed to work with overpressure. Single gas channel configuration can handle overpressure up 1.8 bar.

MD3 for high moisture content – Waste incinerator, Syngas, Coal Power Stations, Chemical and refinery facilities, (…)

MAMOS-CEMS-MD3-Gas-Dryer

MD2 for low and medium moisture content – Biogas, landfill, odour filtration system, LNG, (…)

Three configurations

Compact – Short-extractive CEMS – Analyser with gas dryer on a common mounting plate, all installed near the measurement place.

MAMOS-CEMS-Compact Version

Dimensions (W x H x D) 240 mm x 360 mm x 160 mm
Weight (depends on equipment) 4 kg ÷ 5 kg
Casing’s material ABS
Protection grade IP 20
Mounting plate

 

dimensions (H x W) | material | weight

596 mm x 450 mm | aluminium | 1.9 kg
Operating conditions T: 10°C ÷ 50°C, RH: 5% ÷ 90% (non-condensing)
Storing temperature 0°C ÷ 55°C
Power consumption (analyser unit only) 30 W max
Data-logger: type | size | number of results SD flash card | max 4GB | practically unlimited
Display: type | parameters Backlit LCD | 20 characters x 4 lines
Gas pump: type | max gas flow | standard gas flow Diaphragm | max 2l/min | 1.5l/min (90l/h)
Maximal extraction point pressure: Atmospheric ±200hPa
Current analogue outputs 4 outputs 0mA ÷ 20mA or 4mA ÷ 20mA
Voltage analogue outputs 4 outputs 0V ÷ 5V or 0V ÷ 10V
Digital inputs 2 inputs, TTL levels, floating = high level
Digital outputs 1 open collector output + 2 SPDT relays (optional)
Computer communication interface B type USB socket

Split /1 dryer – Cold Dry Extractive CEMS – Analyser and gas dryer are installed on separate mounting plates, each equipped with its own power supply module.  The gas dryer is installed near the sampling point therefore the analyser can be located away from the source. Once free from water vapour, the sample can be conveyed on long distances without the need for heated lines.

MAMOS-CEMS-Split Version-2

Split/2 dryers – Cold Dry Extractive CEMS – Compact configuration with an additional gas dryer installed on separate mounting plates, each equipped with its own power supply module. Two dryers in serial for high drying performances suitable for Traces monitoring in wet sample.

MAMOS-CEMS-Split Version

Twin Split – Cold Dry Multipoint CEMS – This version is based on the Twin Split/1 dryer configuration, but uses two MD3 dryer with their own power supply added on  separate mounting plates enabling measurements from two different locations (each dryer is installed near the sampling point). User programmable sampling sequences.
Mamos - Mulitplexed CEMS

Madur, state-of-the-art monitoring solutions

logo

1300 850 862

Call us with your application details handy to organise a CEMS demo at your facilities !

AquaGas is supporting the global industrial community with high performance environmental and process monitoring systems (Continuous Emissions Monitoring Systems, Air Quality Monitoring Systems, Online process analysers, Water Quality Monitoring Systems) specifically designed and built to meet your application requirements.

Universal gas sampling system

 

complete gas analysis equipment from one source

Sampling is a key factor to ensure representative analysis and essential to preserve the good status of your monitoring system. AquaGas Monitoring Systems introduces Ankersmid Sampling BVBA (Belgium) stationary sampling equipment designed for Continuous Emission Monitoring (CEMS) and process online analysis.

AquaGas solutions are available as system components for integration into third party systems or as complete turn-key systems. Our systems combine the best technologies available to extract, transfer, and condition samples from stack or crucial process locations prior to analysis.

ACC 400 COMPRESSOR GAS COOLER

Ankersmid Sampling Patented design offers a wide selection of modular options and combinations essential to optimise sampling performances and secure the availability rate of CEMS and process monitoring equipment.

Our adaptative product range is versatile and suits a large variety of applications including:

  • Cement Plant
  • Power Station (Coal fired, Diesel…)
  • Waste Incinerators
  • DeNOx, deSOx and other flue gas treatment process
  • Combustion and Process control
  • Syngas and biogas plant
  • Refineries…

Heated Gas Sample Probes

  • 50°C to 320°C with PID controller or 0-180°C self-limiting heating cartridges
  • High & Low temperature alarm and RS485 ModBus
  • Wide variety of filter materials, length and porosity
  • PTFE demister for wet scrubbers
  • Blowback function for higher dust load up to 10g/Nm3
  • The test gas injection port according to emissions standards (EN14181)
  • Calibration gas feeding via the filter element of the gas sample probe
  • Large selection of heated and unheated sample tubes (incl. ATEX)
  • Easy access to filter, inner stack sample tube, and top-filter
  • Efficient and fast maintenance and routine inspection tasks

Heated Lines

AHL Heatedline-v2

  • 50°C to 200°C Heated Line with PID controller
  • 0-180°C self-limiting heat trace Sample line
  • High & Low temperature alarm and RS485 ModBus
  • Large choice of options and combinations (incl. ATEX)
  • PTFE or SS316 inner tube
  • Multiple inner tubes for calibration, air and sample flows
  • No cold spot
  • Large selection of temperature sensor
  • UV rated PA12 , Polyamide braiding or highly flexible smooth silicon outer jacket
  • Maintenance free and delivered ready for installation

Gas Conditioners

  • 4°C +/-0.1°C dew point stabiliser
  • 19 inch rack  or wall mount units
  • High & Low temperature alarm and RS485 ModBus
  • Large choice of options and combinations (incl. ATEX)
  • Ankersmid Sampling patented NEO® heat exchanger design
  • Multiple stream capabilities
  • PFA® coated gas path and heat exchanger
  • ASS integrated rack mount complete stationary sampling system
  • Low maintenance and reduced operating cost
  • High-performance continuous condensate purge
  • AOX, TUV certified 99% conversion efficiency NOx converter

Gas Sampling Pumps

  • High performance PTFE gas sampling pump
  • 5 to 30 lpm flow range
  • 5 to 240°C operating temperature range
  • Designed for a large range of analytical applications (incl. ATEX)
  • Large choice of options and combinations

Speciality Filters

  • Universal all purposes filters
  • Deep acting particulate filters
  • Calibration gas humidifiers
  • Scrubbers and adsorption material
  • Liquid stop, condensate drain…
  • Built-in liquid alarm sensor, condensate purge, heater…

Ankersmid Sampling

  • Universal

    CEMS integration made easy

  • Performant

    Field proven, high quality, durable Ankersmid Sampling BVBA patented designs

  • Modular

    Comprehensive range of gas sampling equipment from one source

  • Efficient

    Easy to install, maintain and operate

AquaGas is supporting the global industrial community with high performance environmental and process monitoring systems (Continuous Emissions Monitoring Systems, Air Quality Monitoring Systems, Online process analysers, Water Quality Monitoring Systems) specifically designed and built to meet your application requirements.